S1C6S3N2 TECHNICAL HARDWARE
EPSON
I-81
CHAPTER 4: PERIPHERAL CIRCUITS AND OPERATION (SVD Circuit and Heavy Load Protection Function)
Note that the heavy load protection function on the
S1C6S3L2/6S3B2 is different from the S1C6S3N2/6S3A2.
(1) In case of S1C6S3L2/6S3B2
The S1C6S3L2/6S3B2 has the heavy load protection
function for when the battery load becomes heavy and
the source voltage drops, such as when an external
buzzer sounds or an external lamp lights. The state
where the heavy load protection function is in effect is
called the heavy load protection mode. In this mode,
operation with a lower voltage than normal is possible.
The normal mode changes to the heavy load protection
mode in the following two cases:
➀
When the software changes the mode to the heavy load
protection mode (HLMOD = "1")
➁
When supply voltage drop (BLD = "1") in the SVD
circuit is detected, the mode will automatically shift to
the heavy load protection mode until the supply volt-
age is recovered (BLD = "0")
In the heavy load protection mode, the internally regu-
lated voltage is generated by the liquid crystal driver
source output V
L2
so as to operate the internal circuit.
Consequently, more current is consumed in the heavy
load protection mode than in the normal mode. Unless it
is necessary, be careful not to set the heavy load protec-
tion mode with the software. Also, when the BLS is to be
turned on during operation in the heavy load protection
mode, limit the ON time to 10 msec per second of opera-
tion time.
(2) In case of S1C6S3N2/6S3A2
The S1C6S3N2/6S3A2 has the heavy load protection
function for when the battery load becomes heavy and
the source voltage changes, such as when an external
buzzer sounds or an external lamp lights. The state
where the heavy load protection function is in effect is
called the heavy load protection mode. Compared with
the normal operation mode, this mode can reduce the
output voltage variation of the constant voltage/booster
voltage circuit of the LCD system.
The normal mode changes to the heavy load protection
mode in the following case:
Heavy load protec-
tion function