I-30
EPSON
S1C6S3N2 TECHNICAL HARDWARE
CHAPTER 4: PERIPHERAL CIRCUITS AND OPERATION (Oscillation Circuit)
Programming notes
At initial reset, CLKCHG is set to "0".
(1) It takes at least 5 ms from the time the OSC3 oscillation
circuit goes ON until the oscillation stabilizes. Conse-
quently, when switching the CPU operation clock from
OSC1 to OSC3, do this after a minimum of 5 ms have
elapsed since the OSC3 oscillation went ON.
Further, the oscillation stabilization time varies depend-
ing on the external oscillator characteristics and condi-
tions of use, so allow ample margin when setting the wait
time.
(2) When switching the clock form OSC3 to OSC1, use a
separate instruction for switching the OSC3 oscillation
OFF. An error in the CPU operation can result if this
processing is performed at the same time by the one
instruction.