Maintenance 4. Cable
78
LS20 Rev.4
(13) Remove the ground wire from the Arm #2.
(14) Cut off the wire tie binding the cables in the Arm side.
Remove the following parts.
Nylon clip, saddle, ferrite core
Removed parts will be used again. Be careful not to lose them.
Cables are wrapped in a silicon sheet for protection.
The sheet will be reused when installing the cable unit. Be careful not to lose it.
Arm #2 side
Saddle
Silicone sheet
Clip band
Ferrite core
(15) Remove the nut of the rotary
fitting. Remove the rotary
fitting from the Duct Plate.
Pull out the cables from the Duct
Plate.
Nut
2-M4×10
Ground wire
Rotary fittings
Duct Plate
(16) Remove the rotary fitting from the metal duct.
The rotary fitting is directly screwed in the metal duct. Loosen the screws to remove
the fitting.
Cut off the wire tie fixing the cables, and then pull out the cables from the metal duct.
Metal duct
Rotary fitting
Wire tie
Wire tie
(17) Remove the signal connector X20 connected to the resolver board.
NOTE
Summary of Contents for LS20
Page 1: ...Rev 4 EM179R3533F SCARA ROBOT LS20 series MANIPULATOR MANUAL ...
Page 2: ...MANIPULATOR MANUAL LS20 series Rev 4 ...
Page 8: ...vi LS20 Rev 4 ...
Page 12: ...TABLE OF CONTENTS x LS20 Rev 4 ...
Page 14: ......
Page 29: ...Setup Operation 2 Specifications LS20 Rev 4 17 LS20 804S Standard Model ...
Page 31: ...Setup Operation 2 Specifications LS20 Rev 4 19 LS20 804C Cleanroom Model ...
Page 33: ...Setup Operation 2 Specifications LS20 Rev 4 21 LS20 A04S Standard Model ...
Page 35: ...Setup Operation 2 Specifications LS20 Rev 4 23 LS20 A04C Cleanroom Model ...
Page 72: ......
Page 92: ...Maintenance 4 Cable 80 LS20 Rev 4 4 2 Wiring Diagrams 4 2 1 Signal Cable ...
Page 176: ...Maintenance 14 Maintenance Parts List 164 LS20 Rev 4 ...