Maintenance 13. Calibration
160
LS20 Rev.4
(3)-4 Execute the absolute encoder initialization command.
Input one of the following commands to [Command Window] according to the
joint being calibrated.
Joint #1:
>EncReset 1
Joint #2:
>EncReset 2
Joint #3:
>EncReset 3
Joint #4:
>EncReset 3, 4
(3)-5 Reboot the Controller.
Select EPSON RC+ menu-[Tools]-[Controller] and click the <Reset
Controller> button.
* This window will be disappeared when the Controller starts up.
4. Rough Calibration
(4)-1 Execute the following command from the menu-[Tools]-[Command Window].
>calpls 0,0,0,0
* Manipulator does not move.
(4)-2 Execute one of the following commands according to the joint you want to
calibrate from the menu-[Tool]-[Command Window].
Joint #1
>calib 1
Joint #2
>calib 2
Joint #3
>calib 3
Joint #4
>calib 3, 4
5. Calibration (Accurate Positioning)
(5)-1 Turn ON the motors from the EPSON RC+ menu -[Tools]-[Robot
Manager]-[Control Panel].
(5)-2 Click the <Free All> button to free all joints from servo control. Now, you
can move arms by hands.
(5)-3 Move the Manipulator by hand to a rough position/posture of the calibration
point data.
Summary of Contents for LS20
Page 1: ...Rev 4 EM179R3533F SCARA ROBOT LS20 series MANIPULATOR MANUAL ...
Page 2: ...MANIPULATOR MANUAL LS20 series Rev 4 ...
Page 8: ...vi LS20 Rev 4 ...
Page 12: ...TABLE OF CONTENTS x LS20 Rev 4 ...
Page 14: ......
Page 29: ...Setup Operation 2 Specifications LS20 Rev 4 17 LS20 804S Standard Model ...
Page 31: ...Setup Operation 2 Specifications LS20 Rev 4 19 LS20 804C Cleanroom Model ...
Page 33: ...Setup Operation 2 Specifications LS20 Rev 4 21 LS20 A04S Standard Model ...
Page 35: ...Setup Operation 2 Specifications LS20 Rev 4 23 LS20 A04C Cleanroom Model ...
Page 72: ......
Page 92: ...Maintenance 4 Cable 80 LS20 Rev 4 4 2 Wiring Diagrams 4 2 1 Signal Cable ...
Page 176: ...Maintenance 14 Maintenance Parts List 164 LS20 Rev 4 ...