![Epson LQ-2550 Technical Manual Download Page 90](http://html.mh-extra.com/html/epson/lq-2550/lq-2550_technical-manual_109397090.webp)
2.3.1.1
Vx
(Drive System Pull-up) Voltage Supply Circuit
Figure 2-37 shows the Vx voltage supply circuit.
The Vx voltage is used to pull up the bus for the control signals transmitted to the power on reset on
reset circuit, and drive circuits. It is also used to pull up the output of the buzzer drive
(66).
(2A)
ZD
R2
PT SOLENOID DRIVE CIRCUIT
4 . I v
RESET of E05A02LA
R20
O U T P U T
of
IC (6B)
“R21
R21
Figure 2-37. Vx Voltage Supply Circuit
After the printer power is turned on, the + 5V line reaches about
and a potential of about 0.6V
is induced across resistor R21. The difference and
is applied to the Vx line.
When the + 5V line drops to about
or less,
and Q 1 turn off so that the Vx line drops to OV.
Therefore, each
is reset, and the control circuits stop operating.
2-43