REV.-A
4.2.5.17 Paper Thickness Sensor Assembly Removal
Step 1:
Step 2:
Step
Step 4:
Step 5:
Step 6:
Remove the printer mechanism. (Refer to Section 4.2.5. 1.)
Release the lead wires (except the carriage home position sensor wire) from the wire clamp
at the back of the base frame.
Remove the three screws
8) securing the paper thickness sensor unit to the base
frame at the back of the base frame.
Remove the left frame. (Refer to Section 4.2.5 .20.)
Remove the paper guide assembly.
Remove the paper thickness sensor assembly.
Wire Clamp
.
m
m
Home
Position Sensor
Wire
‘..
Figure
Paper Thickness Sensor Assembly
(1)
Paper
\
‘.
. . .
Figure 4-56. Paper Thickness Sensor Assembly Removal (2)
ADJUSTMENT REQUIRED
. When the paper thickness sensor assembly is removed, perform the foIlowing adjustments:
Section 4.3.1 Timing Belt Tension Adjustment (Page 4-40)
Section 4.3.2 Paper Feed Motor Backlash Adjustment (Page 4-4 1)
Section 4.3.3 Parallelism Adjustment Between Carriage Guide Shaft B and Platen (Page 4-42)
Section 4.3.6
Printing Alignment (Page 4-47)
●
When the paper thickness sensor is replaced, perform the following adjustment:
Section 4.3.5 Platen Gap Initial Value Write Operation (Page 4-46).
4-32
Summary of Contents for LQ-2550
Page 1: ...L Q 2 5 5 0 TECHNICAL MANUAL EPSON ...
Page 240: ...REV A P r cl Figure 6 3 LQ 2550 Lubrication and Adhesive Application Points Diagram 2 6 3 ...
Page 241: ...REV A 7 i_ Figure 6 4 LQ 2550 Lubrication and Adhesive Application Points Diagram 3 6 4 ...
Page 252: ...REV A I 1 I 7 v m o m x b Figure A 6 PPD781OHG Block Diagram A 7 ...
Page 297: ...REV A 1 L I Irl N I i t 1 I I x Figure A 50 ROPSE Board Circuit Diagram A 52 ...