![Epson LQ-2550 Technical Manual Download Page 208](http://html.mh-extra.com/html/epson/lq-2550/lq-2550_technical-manual_109397208.webp)
REV.-A
4.3.5 Platen Gap Initial Value Write Operation
The platen gap initial value write operation is required when:
●
Connector CN7 for the battery unit is disconnected.
(The LCD displays “RAM CLEAR” with the power on.)
●
The printer mechanism is removed or replaced.
●
The platen is replaced.
●
The paper thickness sensor assembly is replaced.
The procedure is as follows (see Figure 4-8 1):
Step 1:
Remove the cartridge cover, and insert the adjustment cartridge in slot A (see Figure 4-82).
Step 2:
Confirm that no paper is loaded, and turn the printer power on. The LCD displays
Adjustment”, and the A and V
blink.
Step 3:
Press either the FORM FEED (
❑
) or LINE FEED (
❑
) switch once. The LCD displays
PG Voltage”, and the A and V
blink.
Step 4:
Press the LOAD/EJECT (
) switch. The printer measures the platen gap four times in each
(once per 1/4 rotation of the platen) of the friction and push tractor modes and stores the
mean value of the four measured values for each mode in the memory as the initial platen
gap. When the write operation is completed, the LCD displays
PG Voltage” again,
and the A and V
blink.
Step 5:
Turn the printer power off, and remove the adjustment cartridge from slot A.
Step 1
Step
2
Step
3
Step 4
Step 5
Right Rear Corner of the Printer
1
Insert the adjustment
Figure 4-81. Platen Gap Initial Value
Figure 4-82. Bidirectional Printing Alignment
Write Sequence
Value Adjustment Section
4-46
Summary of Contents for LQ-2550
Page 1: ...L Q 2 5 5 0 TECHNICAL MANUAL EPSON ...
Page 240: ...REV A P r cl Figure 6 3 LQ 2550 Lubrication and Adhesive Application Points Diagram 2 6 3 ...
Page 241: ...REV A 7 i_ Figure 6 4 LQ 2550 Lubrication and Adhesive Application Points Diagram 3 6 4 ...
Page 252: ...REV A I 1 I 7 v m o m x b Figure A 6 PPD781OHG Block Diagram A 7 ...
Page 297: ...REV A 1 L I Irl N I i t 1 I I x Figure A 50 ROPSE Board Circuit Diagram A 52 ...