![Emerson unidrive m200 Parameter Reference Manual Download Page 189](http://html.mh-extra.com/html/emerson/unidrive-m200/unidrive-m200_parameter-reference-manual_102553189.webp)
Parameter
11.093
Additional Identifier Characters 3
Short description
Displays the additional identifier characters
Mode
Open
‑
loop
Minimum
-2147483648
Maximum
2147483647
Default
Units
Type
32 Bit Volatile
Update Rate
Power-up write
Display Format
String
Decimal Places
0
Coding
RO, ND, NC, PT
See
Product Identifier Characters
(11.064).
Parameter
11.094
Disable String Mode
Short description
Set to disable text strings on the keypad
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit User Save
Update Rate
Background
Display Format
Standard
Decimal Places
0
Coding
RW, PT
For all displays.
If
Disable String Mode
(11.094) = 0 then mnemonic strings are on showing the English mnemonic (i.e. OI ac)
If
Disable String Mode
(11.094) = 1 then mnemonic strings are off therefore numbers are used instead.
Parameter
11.097
AI ID Code
Short description
Indicates the AI module type fitted in the AI slot
Mode
Open
‑
loop
Minimum
0
Maximum
5
Default
Units
Type
8 Bit Volatile
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RO, TE, ND, NC, PT, BU
Value
Text
0
None
1
Sd.Card
2
RS-485
3
Res
4
Res
5
485.24V
AI ID Code
(11.097) indicates the Adaptor Interface module type fitted in the AI slot.
Parameter
11.098
24V Loss Alarm Enable
Short description
Enables the 24V loss alarm
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit User Save
Update Rate
Background
Display Format
Standard
Decimal Places
0
Coding
RW
24V Loss Alarm Enable
(11.098) enables the 24V loss alarm. If
24V Supply Input State
(08.043) = 0 and
24V Loss Alarm Enable
(11.098) = 1 then the
alarm is active and
Active Alarm
(10.104) will indicate
24V Backup Lost
.
Parameter
11.099
Modbus Parameter Conversion
Short description
Converts parameter values over Modbus comms for backwards compatibility.
Mode
Open
‑
loop
Minimum
0
(Display: 0000)
Maximum
15
(Display: 1111)
Default
0
(Display: 0000)
Units
Type
16 Bit User Save
Update Rate
Display Format
Binary
Decimal Places
0
Coding
RW
If
Modbus Parameter Conversion
(11.099) bits are turned on then the following parameters are converted when read or written over modbus serial
comms.
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
189
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...