If
Digital input 5 mode
(08.035) = 0 then
Digital Input 5 Invert
(08.015) inverts the destination parameter
Digital Input 05 Destination A
(08.025) or
DI 05 Destination B
(08.125).
If
Digital input 5 mode
(08.035) > 0 then
Digital Input 5 Invert
(08.015) has no effect.
Parameter
08.018
Relay 1 Invert
Short description
Set to 1 to invert relay 1
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
0
Units
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
0
Not.Inv
1
Invert
A value of 0 or 1 in
Relay 1 Invert
(08.018) allows the input state to be non-inverted(0) or inverted(1) respectively.
Parameter
08.020
Digital I/O Read Word
Short description
Displays the states for the digital I/O
Mode
Open
‑
loop
Minimum
0
(Display: 000000000000)
Maximum
2048
(Display: 100000000000)
Default
Units
Type
16 Bit Volatile
Update Rate
Background write
Display Format
Binary
Decimal Places
0
Coding
RO, ND, NC, PT
Digital I/O Read Word
(08.020) reflects the state of DI/O 01 to DI 05 and the relay as given below. Each bit matches the value of the state parameter for the respective digital input or output so the bit value for
digital inputs will be the state of the actual input before any inversion selections are applied. The bit value for digital outputs will include the state inversion if selected in the invert parameter for the output.
Name
Digital I/O Read Word
(08.020) bit
DI/O 01
0
DI 02
1
DI 03
2
DI 04
3
DI 05
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
RLY 01
9
Reserved
10
Because of the limited number of segments on drives with an LED display, these drives will indicate the parameter value as a decimal value rather than a binary
value.
Parameter
08.021
Digital IO1 Source/Destination A
Short description
Defines the source or destination parameter for Digital I/O 1
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
10.003
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT
Digital IO1 Source/Destination A
(08.021) provides the destination parameter if DI/O 1 is an input when
Digital I/O 01 mode
(08.031) = 0, and
DI1 Control
(08.081) is at it's default value of 0.
Digital IO1 Source/Destination A
(08.021) provides the source parameter if DI/O 1 is an output when
Digital I/O 01 mode
(08.031) ≥ 1,and
DO1 Control
(08.091) is at it's default value of 0.
Parameter
08.022
Digital IO2 Source/Destination A
Short description
Defines the source or destination parameter for Digital I/O 2
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
6.038
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT
Digital IO2 Source/Destination A
(08.022) provides the destination parameter if
DI2 Control
(08.082) is at its default value of 0.
Parameter
08.023
Digital Input 03 Destination A
Short description
Defines the destination parameter for digital Input 3
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
6.030
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT
Digital Input 03 Destination A
(08.023) provides the destination parameter if
DI3 Control
(08.083) is at its default value of 0.
Parameter
08.024
Digital Input 04 Destination A
Short description
Defines the destination parameter for Digital Input 4
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
6.032
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT
Digital Input 04 Destination A
(08.024) provides the destination parameter if
DI4 Control
(08.084) is at its default value of 0.
116
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...