Power Stage Identifier
(11.066) is used to show power stages that require changes to the drive user parameters (i.e. visibility, range or defaults). It is
anticipated that all power stages will require the same parameter structure, and so
Power Stage Identifier
(11.066) will always be equal to zero. It should
be noted that this parameter does not identify the rating of the power stage.
Power Stage Identifier
(11.066)
Power stage
0
Standard M600-M800
1
Standard M100-M400
2
Standard ID300,ID302
Parameter
11.067
Control Board Identifier
Short description
Displays the control board identifiers within the drive
Mode
Open
‑
loop
Minimum
0
Maximum
255
Default
Units
Type
8 Bit Volatile
Update Rate
Power-up write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT, BU
Control Board Identifier
(11.067) identifies the main control board hardware as given in the table below.
Control Board Identifier
(11.067)
Control
board
0
Reserved
1
Reserved
2
M100
3
Reserved
4
Reserved
5
M101
6
Reserved
7
Reserved
8
M200
9
Reserved
10
Reserved
11
M201
12
Reserved
13
Reserved
14
M300
15
Reserved
16
Reserved
17
M400
18
ID300/ID302
Parameter
11.068
Drive current rating
Short description
Drive current rating in 0.1 of Amps
Mode
Open
‑
loop
Minimum
0
(Display: 00000)
Maximum
32767
(Display: 32767)
Default
Units
Type
16 Bit Volatile
Update Rate
Power-up write
Display Format
Lead Zero Pad
Decimal Places
0
Coding
RO, ND, NC, PT
See
Product Identifier Characters
(11.064).
Parameter
11.070
Core Parameter Database Version
Short description
Displays the core parameter database version within the drive
Mode
Open
‑
loop
Minimum
0.00
Maximum
99.99
Default
Units
Type
16 Bit Volatile
Update Rate
Power-up write
Display Format
Standard
Decimal Places
2
Coding
RO, ND, NC, PT
Core Parameter Database Version
(11.070) gives the version number of the parameter database used to define the core parameter menus in the drive
(Menu 1 to 14 and 21 to 23) in 2 digit BCD format. All other menus are customisable and if these menus are changed their default values are
automatically loaded. However, if the drive software is changed it may be necessary to load defaults for all menus, although this will only be required
rarely. Defaults for all menus are loaded when the most significant digit of
Core Parameter Database Version
(11.070) changes. Therefore if the drive
firmware is modified and the most significant digit of the core database version has changed an
EEPROM Fail
.001 trip is initiated and default
parameters are loaded.
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
185
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...