Pre-skip Filter Reference
(01.002) is the reference before the skip filtering as indicated in Fig. 1.2.
Parameter
01.003
Pre-ramp Reference
Short description
Displays the final output from the reference system
Mode
Open
‑
loop
Minimum
−VM_SPEED_FREQ_REF
Maximum
VM_SPEED_FREQ_REF
Default
Units
Hz
Type
32 Bit Volatile
Update Rate
4ms write
Display Format
Standard
Decimal Places
2
Coding
RO, VM, ND, NC, PT
Fig.1.3 shows the process from the
Pre-skip Filter Reference
(01.002) to the
Pre-ramp Reference
(01.003). The
Pre-ramp Reference
(01.003) is the final output
from the Menu 01 reference system that is fed into the Menu 02 ramp system.
Parameter
01.004
Reference Offset
Short description
Defines the the offset applied to the reference
Mode
Open
‑
loop
Minimum
−VM_SPEED_FREQ_REF
Maximum
VM_SPEED_FREQ_REF
Default
0.00
Units
Hz
Type
32 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
2
Coding
RW, VM
If
Reference Offset Select
(01.009) = 0 then
Reference Selected
(01.001) is the selected reference multiplied by [1 +
Percentage Trim
(01.038) / 100.00)].
If
Reference Offset Select
(01.009) = 1 then the
Reference Offset
(01.004) is added to the selected reference to give
Reference Selected
(01.001).
If
Reference Offset Select
(01.009) = 2 then
Reference Selected
(01.001) is the selected reference plus the M
aximum reference frequency
multiplied by
(
Percentage Trim
(01.038) / 100.00).
Maximum reference frequency
is normally the value of
Maximum Speed
(01.006) but refer to Variable
Maximum VM_SPEED_FREQ_REF for a full definition.
Parameter
01.005
Jog Reference
Short description
Defines the reference when jog is enabled
Mode
Open
‑
loop
Minimum
0.00
Maximum
300.00
Default
1.50
Units
Hz
Type
16 Bit User Save
Update Rate
4ms read
Display Format
Standard
Decimal Places
2
Coding
RW, BU
Parameter
01.006
Maximum Speed
Short description
Defines the maximum value for the reference
Mode
Open
‑
loop
Minimum
−VM_POSITIVE_REF_CLAMP
Maximum
VM_POSITIVE_REF_CLAMP
Default
See exceptions below
Units
Hz
Type
32 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW, VM
Region
Default Value
50Hz
50.00
60Hz
60.00
Maximum Speed
(01.006) provides a limit on the maximum speed demand. (If
Select Motor 2 Parameters
(11.045) = 1 then
M2 Maximum Speed
(21.001) is
used instead.)
Parameter
01.007
Minimum Speed
Short description
Defines the minimum value for the reference
Mode
Open
‑
loop
Minimum
−VM_NEGATIVE_REF_CLAMP1
Maximum
VM_NEGATIVE_REF_CLAMP1
Default
0.00
Units
Hz
Type
32 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW, VM
If
Negative Reference Clamp Enable
(01.008) = 1 then
Minimum Speed
(01.007) is forced to be a negative value and is applied to the final reference as the
negative limit. If
Negative Reference Clamp Enable
(01.008) = 0 then -
Maximum Speed
(01.006) is applied to the final reference as the negative limit. (If
Select Motor 2 Parameters
(11.045) = 1 then
M2 Minimum Speed
(21.002) is used instead.)
The minimum speed is also used to provide the minimum speed limit for uni-polar mode (i.e.
Bipolar Reference Enable
(01.010) = 0) after
the
Reference Selected
(01.001) as shown in Fig.1.2.
18
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...