![Emerson unidrive m200 Parameter Reference Manual Download Page 118](http://html.mh-extra.com/html/emerson/unidrive-m200/unidrive-m200_parameter-reference-manual_102553118.webp)
Parameter
08.043
24V Supply Input State
Short description
Displays the state for the 24V Supply Input
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
Units
Type
1 Bit Volatile
Update Rate
Background write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT
Digital Input 13 (24V Supply Input) is an external 24V supply input that is monitored and can be used as a 24V digital input if an external 24V supply is not required. The state parameter is low for the voltage
range from 0V to 17V and high for the voltage range above 18V. As the input is a power supply it will consume significant current if the level is taken above 24V when the drive is running from its internal power
supply, or at any voltage level if this input is the only power supply to the drive. The 24V Input is available on the AI SD card adaptor. The 24V alarm is triggered if
24V Loss Alarm Enable
(11.098) = 1 and
24V Supply Input State
(08.043) = 0.
Parameter
08.044
Keypad Stop Button State
Short description
Displays the state for the Keypad Stop button
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
Units
Type
1 Bit Volatile
Update Rate
Background write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT
See
Keypad Run Button State
(08.041).
Parameter
08.051
Keypad Run Button Invert/Toggle
Short description
Set to invert/toggle Keypad Run Button
Mode
Open
‑
loop
Minimum
0
Maximum
2
Default
0
Units
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
0
Not.Inv
1
Invert
2
Toggle
When a button state is used to change a parameter (see
Keypad Run Button Destination
(08.061)) the state can be used in any one of modes selected by
Keypad Run Button Invert/Toggle
(08.051).
0 The parameter will be the same as the input state.
1 The parameter will be the inverse of the input state.
2 The parameter will toggle each time the state transitions from 0 to 1.
Parameter
08.052
Keypad Auxiliary Button Invert/Toggle
Short description
Set to invert/toggle Keypad Auxiliary Button
Mode
Open
‑
loop
Minimum
0
Maximum
2
Default
0
Units
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
0
Not.Inv
1
Invert
2
Toggle
When a button state is used to change a parameter (see
Keypad Auxiliary Button Destination
(08.062)) the state can be used in any one of modes selected by
Keypad Auxiliary Button Invert/Toggle
(08.052).
0 The parameter will be the same as the input state.
1 The parameter will be the inverse of the input state.
2 The parameter will toggle each time the state transitions from 0 to 1.
Parameter
08.053
24V Supply Input Invert
Short description
Set to invert 24V Supply Input
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
0
Units
Type
8 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
0
Not.Inv
1
Invert
When a button state is used to change a parameter (see
24V Supply Input Destination
(08.063)) the state can be used in any one of modes selected by
24V Supply Input Invert
(08.053).
0 The parameter will be the same as the input state.
1 The parameter will be the inverse of the input state.
Parameter
08.061
Keypad Run Button Destination
Short description
Defines the destination parameter for digital input 11
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
0.000
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT
This destination parameter provides the routing for the Keypad Run (DI 11) input, see
Keypad Run Button Invert/Toggle
(08.051).
118
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...