Menu 11 −
Miscellaneous
Mode: Open
‑
loop
Parameter
11.018
Status Mode Parameter 1
Short description
Defines the parameter displayed on the upper row of the keypad when in status mode
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
2.001
Units
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
3
Coding
RW, PT, BU
Status Mode Parameter 1
(11.018) and
Status Mode Parameter 2
(11.019) defines which parameters are displayed in Status mode.
The values can be alternated by pressing the Escape key if the drive status is RUN.
If one of the two Status parameter does not exist or is 0.000, only one Status parameter is displayed.
If the two Status parameters do not exist or are 0.000, the active parameter is displayed.
Parameter
11.019
Status Mode Parameter 2
Short description
Defines the parameter displayed on the lower row of the keypad when in status mode
Mode
Open
‑
loop
Minimum
0.000
Maximum
30.999
Default
4.020
Units
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
3
Coding
RW, PT, BU
See
Status Mode Parameter 1
(11.018).
Parameter
11.020
Reset Serial Communications
Short description
Set to one to update communications set-up
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
Units
Type
1 Bit Volatile
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, ND, NC
When
Serial Address
(11.023),
Serial Mode
(11.024),
Serial Baud Rate
(11.025),
Minimum Comms Transmit Delay
(11.026) or
Silent Period
(11.027)
are modified the changes do not have an immediate effect on the serial communications system. The new values are used after the next power-up or if
Reset Serial Communications
(11.020) is set to one.
Reset Serial Communications
(11.020) is automatically cleared to zero after the communications
system is updated.
Parameter
11.021
Customer defined scaling
Short description
Defines the scaling of 11.018 in status view
Mode
Open
‑
loop
Minimum
0.000
Maximum
10.000
Default
1.000
Units
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
3
Coding
RW
Customer defined scaling
(11.021) defines the scaling applied to
Status Mode Parameter 1
(11.018). The scaling is only applied in the Status mode.
Parameter
11.022
Active Parameter At Power-up
Short description
Defines which parameter is displayed at power-up in view mode
Mode
Open
‑
loop
Minimum
0.000
Maximum
0.095
Default
0.010
Units
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
3
Coding
RW, PT, BU
Active Parameter At Power-up
(11.022) defines which Menu 0 parameter is initially active at power-up in view mode. If
Active Parameter At Power-up
(11.022) > 10 and
User Security Status
(11.044) is set to
Level 1
then Parameter 10 is set as the power up parameter.
See
Status Mode Parameter 1
(11.018).
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
173
Summary of Contents for unidrive m200
Page 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Page 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Page 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Page 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Page 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Page 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...