Apparent power
Figure 4-11:
90
20
22
24
26
28
30
34
32
110
130
150
170
B
190
210
230
250
A
A.
Apparent power (VA)
B.
Power supply (VAC)
DC power supply requirements
Standard DC units powered by 12VDC power supply may draw up to 1.2A of current steady
state. Low power DC units may draw up to 0.25A of current steady state. Peak inrush is
42A at 42VDC supply, lasting approximately 1ms. Inrush for other supply voltages can be
estimated with: Inrush (Amps) = Supply (Volts) / 1.0
DC current requirements
Figure 4-12:
12
0.2
0.3
0.4
0.5
0.6
0.7
0.9
1.0
1.1
1.2
0.8
17
22
27
B
32
37
42
A
A.
Supply current (amps)
B.
Power supply (VDC)
Remote Transmitter Installation
Reference manual
39
Summary of Contents for Rosemount 8732EM
Page 2: ......
Page 6: ...Contents iv Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 10: ...Safety messages 4 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 14: ...Introduction 8 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 30: ...Sensor Installation 24 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 92: ...Operation 86 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 158: ...Maintenance 152 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 214: ...Product Certifications 208 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 217: ...Wiring 8732EM using combination cable Figure C 2 Wiring Diagrams Reference manual 211 ...
Page 222: ...Wiring Diagrams 216 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 253: ...Implementing a Universal Transmitter Reference manual 247 ...