Process connections—Mounts between these flange configurations
ASME B16.5
Class 150, 300
EN 1092-1
PN10, PN16, PN25, PN40
JIS B2220
10K, 20K
AS4087
PN16, PN21, PN35
Studs, nuts, and washers—MK2-carbon steel
Component
ASME B16.5
EN1092-1
Studs, full thread CS, ASTM A193, Grade B7
CS, ASTM A193, Grade B7
Hex nuts
ASTM A194 Grade 2H
ASTM A194 Grade 2H; DIN 934 H = D
Flat washers
CS, Type A, Series N, SAE per ANSI
B18.2.1
CS, DIN 125
All items
Clear, chromate zinc-plated
Yellow zinc-plated
Studs, nuts, and washers—MK3-316 SST
Component
ASME B16.5
EN1092-1
Studs, full thread ASTM A193, Grade B8M Class 1
ASTM A193, Grade B8M Class 1
Hex nuts
ASTM A194 Grade 8M
ASTM A194 Grade 8M; DIN 934 H = D
Flat washers
316 SST, Type A, Series N, SAE per ANSI
B18.2.1
316 SST, DIN 125
A.5
8721 Hygienic (Sanitary) Sensor Specifications
Product Specifications
202
Rosemount
®
8732EM Transmitter with HART Protocol Reference Manual
Summary of Contents for Rosemount 8732EM
Page 2: ......
Page 6: ...Contents iv Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 10: ...Safety messages 4 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 14: ...Introduction 8 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 30: ...Sensor Installation 24 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 92: ...Operation 86 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 158: ...Maintenance 152 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 214: ...Product Certifications 208 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 217: ...Wiring 8732EM using combination cable Figure C 2 Wiring Diagrams Reference manual 211 ...
Page 222: ...Wiring Diagrams 216 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 253: ...Implementing a Universal Transmitter Reference manual 247 ...