11.3
Installing a Local Operator Interface (LOI)
Installing a Local Operator Interface (LOI)
Figure 11-1:
Procedure
1.
If the transmitter is installed in a control loop, secure the loop.
2.
Remove power from the transmitter.
3.
Remove the cover on the electronics compartment of the transmitter housing. If the
cover has a cover jam screw, loosen it before removing the cover.
for details on the cover jam screw.
4.
On the electronics stack, locate the serial connection labeled “DISPLAY”.
.
5.
Plug the serial connector from the back of the LOI into the receptacle on the
electronics stack.
The LOI can be rotated in 90 degree increments to provide the best viewing
position. Rotate the LOI to the desired orientation, taking care to not exceed 360
degrees of rotation. Exceeding 360 degrees of rotation could damage the LOI cable
and/or connector.
6.
Once the serial connector is installed on the electronics stack, and the LOI is oriented
in the desired position, tighten the three mounting screws.
7.
Install the extended cover with the glass viewing pane and tighten to metal-to-
metal contact.
If the cover has a cover jam screw, this must be tightened to comply with installation
requirements. Return power to the transmitter and verify that it is functioning
correctly and reporting the expected flow rate.
8.
If installed in a control loop, return the loop to automatic control.
Maintenance
142
Rosemount
®
8732EM Transmitter with HART Protocol Reference Manual
Summary of Contents for Rosemount 8732EM
Page 2: ......
Page 6: ...Contents iv Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 10: ...Safety messages 4 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 14: ...Introduction 8 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 30: ...Sensor Installation 24 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 92: ...Operation 86 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 158: ...Maintenance 152 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 214: ...Product Certifications 208 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 217: ...Wiring 8732EM using combination cable Figure C 2 Wiring Diagrams Reference manual 211 ...
Page 222: ...Wiring Diagrams 216 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 253: ...Implementing a Universal Transmitter Reference manual 247 ...