High limit
LOI menu path
Flow 1: Detailed Setup > Output Config > DI/DO Config > Flow
Limit 1 > High Limit 1
Flow 2: Detailed Setup > Output Config > DI/DO Config > Flow
Limit 2 > High Limit 2
Set the flow rate value that corresponds to the high limit set point for the flow limit alert.
Low limit
LOI menu path
Flow 1: Detailed Setup > Output Config > DI/DO Config > Flow
Limit 1 > Low Limit 1
Flow 2: Detailed Setup > Output Config > DI/DO Config > Flow
Limit 2 > Low Limit 2
Set the flow rate value that corresponds to the low limit set point for the flow limit alert.
Flow limit hysteresis
LOI menu path
Flow 1: Detailed Setup > Output Config > DI/DO Config > Flow
Limit 1 > Hysteresis
Flow 2: Detailed Setup > Output Config > DI/DO Config > Flow
Limit 2 > Hysteresis
Set the hysteresis band for the flow limit to determine how quickly the transmitter comes
out of alert status. The hysteresis value is used for both flow limit 1 and flow limit 2.
Changing this parameter under the configuration parameters for one channel will cause it
to also change in the other channel.
Total limit
Configure the parameters that will determine the criteria for activating a HART alert if
Totalizer A falls within a set of configured criteria. This functionality can be used for
operating simple batching operations or generating alerts when certain localized values
are met. This parameter can be configured as a discrete output if the transmitter was
ordered with auxiliary outputs enabled (option code AX). If a digital output is configured
for total limit, the digital output will activate when the conditions for total mode are met.
Total control
LOI menu path
Detailed Setup > Output Config > DI/DO Config > Total Limit >
Total Control
This parameter turns the total limit HART alert ON or OFF.
Advanced Configuration Functionality
100
Rosemount
®
8732EM Transmitter with HART Protocol Reference Manual
Summary of Contents for Rosemount 8732EM
Page 2: ......
Page 6: ...Contents iv Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 10: ...Safety messages 4 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 14: ...Introduction 8 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 30: ...Sensor Installation 24 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 92: ...Operation 86 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 158: ...Maintenance 152 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 214: ...Product Certifications 208 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 217: ...Wiring 8732EM using combination cable Figure C 2 Wiring Diagrams Reference manual 211 ...
Page 222: ...Wiring Diagrams 216 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 253: ...Implementing a Universal Transmitter Reference manual 247 ...