D.11
Kent sensors
D.11.1
Kent sensor to 8732 Transmitter
To connect a Kent sensor to a Rosemount 8732 Transmitter, connect coil drive and
electrode cables as shown in
.
CAUTION!
Do not connect mains or line power to the magnetic flowtube sensor or to the transmitter coil
excitation circuit.
Generic Wiring Diagram for Kent Sensors and Rosemount 8732
Figure D-18:
C
A
B
D
17
18
19
3
2
1
SIG2
SCR OUT
1
2
SIG1
SCR OUT
A.
Kent sensors
B.
Rosemount 8732 transmitter
C.
Electrode connections
D.
Coil connections
Note
Refer to
for actual terminal block configuration drawing.
Kent Sensor Wiring Connections
Table D-18:
Rosemount 8732
Kent sensors
1
1
2
2
3
SCR OUT
17
SCR OUT
18
SIG1
19
SIG2
Implementing a Universal Transmitter
Reference manual
239
Summary of Contents for Rosemount 8732EM
Page 2: ......
Page 6: ...Contents iv Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 10: ...Safety messages 4 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 14: ...Introduction 8 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 30: ...Sensor Installation 24 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 92: ...Operation 86 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 158: ...Maintenance 152 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 214: ...Product Certifications 208 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 217: ...Wiring 8732EM using combination cable Figure C 2 Wiring Diagrams Reference manual 211 ...
Page 222: ...Wiring Diagrams 216 Rosemount 8732EM Transmitter with HART Protocol Reference Manual ...
Page 253: ...Implementing a Universal Transmitter Reference manual 247 ...