EK280
Application Manual
142
The counter progress compared to the respective previous entry is denoted with a "
". Normally it is a flow
(consumption) in this case within a day. This, however, does not apply when an archive row is entered due to
a particular event (e.g. setting the clock or a counter, appearance of an important status message). The meter
reading flashes with the meter progress to point out this feature to the user (for further information, refer to the
instruction manual "usage as a registration device").
9.2.2
Memory capacity
Based on factory settings, the archive contains 600
data rows, which corresponds to a memory capacity of
approx. 19 months.
i
The daily archive is a ring-type memory. If the archive is full then the oldest entries are overwritten.
9.2.3
Changing the daily limit
All values relating to daily limits can be created with the daily limit which can be set here.
In order to set the daily limit on the device to another value, open the administrator lock as described
in the EK280 operating manual.
Move the cursor to
"Serv."
>
"Archive" > "DayB".
Press the ENTER button
One digit of the value flashes.
Move the cursor with the arrow buttons
or
to the digits and change these with the arrow buttons
or
.
Press the ENTER button to confirm the set value. It is possible to abort the entry by pressing the
ESC button.
9.2.4
Values relating to daily limits
To display the volumes relating to the daily limit, move the cursor to
"Serv."
>
"Volume" > "per day".
Display
Description
VbDyc
Vb Daily interval meter progress of the current month
VbDy
Vb Daily interval meter progress of the previous month
VbDyc
Maximum VbDy of current month
VbDy
Maximum VbDy of last month
VmDyc
Vm Daily interval meter progress of the current month
VmDy
Vm Daily interval meter progress of the previous month
VmDyc
Maximum VmDy of current month
VmDy
Maximum VmDy of last month
W.Dyc
32
W Daily interval meter progress of the current month
W.Dy
W Daily interval meter progress of the previous month
W.Dyc
Maximum W.Dy of current month
W.Dy
Maximum W.Dy of last month
DayB
Day boundary, indicates the begin of the gas day
The counter progress compared to the respective previous entry is denoted with a "
". Normally it is a flow
(consumption) in this case within a day. This, however, does not apply when an archive row is entered due to
a particular event (e.g. setting the clock or a counter, appearance of an important status message). The meter
reading flashes with the meter progress to point out this feature to the user (for further information, refer to the
instruction manual "usage as a registration device").
32
This value is only displayed when the
“
Menu option 1: With energy
” is set. Use enSuite
Parameters > Device
settings > Display > Menu options
.