EK280
Application Manual
108
Once the communication link is set up, you can carry out checks, for instance view certain
parameters. To do this press "
Navigation
" on the left-hand side of the enSuite window and then
"
Parameterize online
" in the bottom of the navigation window, then click on the plus sign next to
"
Parameters
" and then its subsections.
In enSuite press the "
Disconnect
" symbol or "
Disconnect from all devices
" to end the test retrieval.
7.4.2
Ex isolator MTL5051
The MTL5051 is an approved "associated apparatus" and can therefore be used as an interface isolator, if the
EK280 is installed in Zone 1.
7.4.2.1 Connection
Explosion hazard!
If EK280 operation takes place in a potentially explosive atmosphere, ensure that all
safety instructions in the EK280 Operating Instructions are followed.
24 V =
MTL5051
-
+
13 14
EK280
1
2
3
4
5
6
7
8
9
10
11
12
RS232
device,
i.e. PC
TxD
DTR
RxD
DCD
TxD
Ri
GnD
GND
RxD
Uext+
Uext-