EK280
Application Manual
131
Designation
Modbus_Master_
TaskList_ …
Meaning
Address Value Content
...MdbStartAdr
Modbus-Adr.
2:8C5
2
1:100
Stat - Momentary status, total
...MdbNoReg
Disp.
Register
2:8C6
1
1 Register
...MdbRegRWMode RW-Mode
2:8C7
2
2: Write-FC06
...MdbStartAdr
Modbus-Adr.
3:8C5
3
4:302_2
VmT - Total actual volume (post-
decimal places) [10E-4 m3]
...MdbNoReg
Disp.
Register
3:8C6
1
1 Register
...MdbRegRWMode RW-Mode
3:8C7
2
2: Write-FC06
...MdbStartAdr
Modbus-Adr.
4:8C5
4
2:302_2
VbT - Total volume at base conditions
(post-decimal places) [10E-4 m3]
...MdbNoReg
Disp.
Register
4:8C6
1
1 Register
...MdbRegRWMode RW-Mode
4:8C7
2
2: Write-FC06
...MdbStartAdr
Modbus-Adr.
5:8C5
5
1:302_2
W.T - Total Energy (post-decimal
places) [10E-4 kWh]
...MdbNoReg
Disp.
Register
5:8C6
1
1 Register
...MdbRegRWMode RW-Mode
5:8C7
2
2: Write-FC06
...MdbStartAdr
Modbus-Adr.
6:8C5
101
4:302_1
VmT - Total actual volume (pre-decimal
places) [m³]
...MdbNoReg
Disp.
Register
6:8C6
2
2 registers
...MdbRegRWMode RW-Mode
6:8C7
3
3: Write-FC16
...MdbStartAdr
Modbus-Adr.
7:8C5
103
2:302_1
VbT - Total volume at base conditions
(pre-decimal places) [m³]
...MdbNoReg
Disp.
Register
7:8C6
2
2 registers
...MdbRegRWMode RW-Mode
7:8C7
3
3: Write-FC16
...MdbStartAdr
Modbus-Adr.
8:8C5
105
1:302_1
W.T - Total Energy (pre-decimal
places) [kWh]
...MdbNoReg
Disp.
Register
8:8C6
2
2 registers
...MdbRegRWMode RW-Mode
8:8C7
3
3: Write-FC16
...MdbStartAdr
Modbus-Adr.
9:8C5
301
7:312_1
pb - Pressure at base conditions [bar]
...MdbNoReg
Disp.
Register
9:8C6
2
2 registers
...MdbRegRWMode RW-Mode
9:8C7
3
3: Write-FC16
...MdbStartAdr
Modbus-Adr.
10:8C5
303
6:312_1
Tb - Temperature at base conditions
[°C]
...MdbNoReg
Disp.
Register
10:8C6
2
2 registers
...MdbRegRWMode RW-Mode
10:8C7
3
3: Write-FC16
...MdbStartAdr
Modbus-Adr.
11:8C5
305
6:210_1
p.Abs - Absolute pressure
measurement [bar]
...MdbNoReg
Disp.
Register
11:8C6
2
2 registers
...MdbRegRWMode RW-Mode
11:8C7
3
3: Write-FC16
...MdbStartAdr
Modbus-Adr.
12:8C5
307
6:211_1
p.Mes - Pressure - measured value
[bar]
...MdbNoReg
Disp.
Register
12:8C6
2
2 registers