56
Installation Manual
Inverter / Connect Battery to Inverter
1. Connect long positive (red) and negative (black) ferrule ends of the
battery cable to the in and - BAT INPUT as shown below.
Use pre-made battery-to-inverter cables. The battery cables through
battery port Connect battery cables to battery terminals. If the
battery is required to connect with PE cable, connect PE cable to
ground bar.
GND Torque: 0.25 in set screw, torque min. 3.3 max. 4.0
Nm (min. 2.4 max. 3.0 ft lb).
3.3.5.1. CONNECT BATTERY TO INVERTER
2. Plug in the long positive (red) and negative (black) cables into the
same color BMS connectors as shown below
CAUTION:
Do not turn on the switches at this time.
Inverter connections from the battery
ZN: “OUT COMM”
Topband: “OUT COM1”