129
Installation Manual
Appendix / Technical Specifications (AC)
Product Model
PP2-
AC-10/15/20-9600
PP2-
AC-10/15/20-8600
PP2-
AC-10/15/20-7600
PP2-
AC-10/15/20-7000
PP2-
AC-10/15/20-6000
PP2-
AC-10/15/20-5000
DC INPUT / BATTERY
Rated Charge / Discharge
50 A / 50 A
Maximum Charge /
Discharge
50 A / 50 A
DC Voltage Range
80-495
Battery Capacity (Range)
10 to 20 kWh
Battery Types Supported
Lithium-ion (LFP)
DC Circuit Breaker
Yes
DC Fuse on Plus Terminal
Internal Fuse, not field replaceable
EFFICIENCY
Battery Charge/discharge
to AC Max. Efficiency
96.6%
CEC Efficiency
96.1%
OPERATIONAL FEATURES
AND MODES
Islanding
Neutral Forming Transformer
Back-up (default)
Yes
Self Consumption
Yes
Prioritized Charging from
Renewables
Yes
Grid Support - Zero Export
Yes
Time-Of-Use Grid Export
Yes
Genset Integration
No
Grid Support/Demand
Response
Yes
Home current monitoring
(L1 & L2 CTs)
Yes
Over Current Protection
Yes
Short Protection
Yes
Over Voltage Protection
Yes
Battery Reverse Polarity
Protection
Yes
ADDITIONAL AND
OPTIONAL FEATURES
Supported Communication
Interfaces
WiFi & Cellular
System Monitoring and
Network Communications
Cloud-Based Dashboard
Interface Protocol
Proprietary
Loads Disconnect Isolation
Yes
Inverter Bypass Switch
Automatic
Rapid Shutdown
functionality for NEC 2014
690.12
External option
Arc Fault Protection (Type
1) for NEC 2011 690.11
compliance
Yes
Insulation Resistance
Detection
Yes
Revenue Grade Data,
ANSI C12.
Optional
NEMA 3R Enclosure
Standard