6.
Hook and needle bar
6.1
Needle position
Standard:
The needle (80 Nm) should have a distance of 1.8 mm to the front
edge of the knife.
Setting:
–
Loosen screw 3 through drill-hole 4 in the arm.
–
Shift the needle bar linkage 5 according to the instructions.
–
Tighten screw 3 again.
Attention
After correcting the needle position check the distance between hook
and needle (chapter 6.4) and adjust it, if required.
6.2
Reference position of the needle bar
Standard proximity switch :
The distance between the proximity switch 6 and the switching
edge 7 should amount 0.7 mm.
Functional check :
Select the input 17 in the Multitest-Input test. On recognition of the
switching edge the switching status must change form “-” to “+”.
21
3
3
5
4
6
7
Summary of Contents for 540-100-1
Page 1: ...540 100 1 Komplettanleitung Manual complete...
Page 28: ...5 Knopflochprogrammierung 5 1 Knopfloch Aufbau 26...
Page 48: ...Notizen 46...
Page 50: ...8 1 2 11 7 9 10 5 12 4 3 6...
Page 62: ...F r Notizen 14...
Page 108: ...F r Notizen 36...
Page 118: ...Notizen 46...
Page 144: ...5 Buttonhole programming 5 1 Composition of a buttonhole 26...
Page 164: ...Notes 46...
Page 166: ...8 1 2 11 7 9 10 5 12 4 3 6...
Page 178: ...Notes 14...
Page 224: ...Notes 36...