5.
Knife setting
5.1
Aligning the knife and adjusting the knife height
Standard:
The knife should penetrate the knife slot centrally.
During the cutting open the knife should remain in the knife slot for a
depth of 0.2 mm in its upper dead center.
Setting:
–
Remove the knife.
–
Move the knife block down via parameter T3.1.1 outputs of the
submenu Multitest
–
Loosen screw 2.
–
Insert the knife in the knife slot, press it against the knife holder
and displace the knife holder until the knife is in the centre of the
slot.
–
Tighten screw 2 and mount the knife.
Knife height adjustment:
–
Loosen screw 1.
–
Set the knife height in such a way that the knife remains in the
knife slot for a depth of 0.2 mm during the cutting open.
–
Tighten screw 1.
ATTENTION!
When adjusting the height the knife holder must not be turned.
The knife must penetrate the knife slot in parallel position.
Check the knife penetration after the height setting.