8.
Error messages
Number
Error position
Description
Cause
Error elimination
1052
Sewing motor
Overcurrent
- Sewing motor cable
- Sewing motor
- Control
- Check sewing motor cable
- Check sewing motor
- Check control
1053
Sewing motor
Overvoltage
Mains too high
- Check mains voltage
1055
Sewing motor
Overload
- Sewing motor (blocked/
rough running)
- Control
- Check sewing motor
- Check control
1056
Sewing motor
Excess temperature
- Sewing motor
(rough running)
- Control
- Check sewing motor
- Check control
1058
Sewing motor
Speed
- Sewing motor
- Check sewing motor
1059
Sewing motor
Standstill-
monitoring
- Sewing motor
- Reference switch
- Check sewing motor
- Check reference switch
1120
Sewing motor
Initialization
- Sewing motor
- Sewing motor cable
- Reference switch
- Check sewing motor
- Check sewing motor cable
- Check reference switch
1205
Sewing motor
Not in UDC
(Upper Dead Center)
- Sewing motor
- Sewing motor cable
- Reference switch
- Switch machine off/on
- Check sewing motor
- Check sewing motor cable
- Check reference switch
1301
Sewing motor
Referencing
timeout
- Reference switch
- Sewing motor
- Control
- Check reference switch
- Check sewing motor
- Check control
1302
Sewing motor
Current feed
error
- Sewing motor
- Sewing motor cable
- Control
- Check sewing motor
- Check sewing motor cable
- Check control
1310
Sewing motor
Communication-
problem
- Sewing motor
- Sewing motor cable
- Reference switch
- Check sewing motor
- Check sewing motor cable
- Check reference switch
1320
Sewing motor
General sewing motor
error
- Sewing motor
- Sewing motor cable
- Reference switch
- Check sewing motor
- Check sewing motor cable
- Check reference switch
2101
Step motor
x-axis
Referencing
timeout
- Reference switch
- Step motor
- Control
- Check reference switch
- Check step motor
- Check control
2152
Step motor
x-axis
Overcurrent
- Step motor
- Control
- Check step motor
- Check control
2153
Step motor
x-axis
Overvoltage
- Step motor
- Control
- Check step motor
- Check control
2155
Step motor
x-axis
Overload
- Step motor
- Control
- Check step motor
- Check control
2156
Step motor
x-axis
Excess temperature
- Step motor
- Control
- Check step motor
- Check control
41
1
Summary of Contents for 540-100-1
Page 1: ...540 100 1 Komplettanleitung Manual complete...
Page 28: ...5 Knopflochprogrammierung 5 1 Knopfloch Aufbau 26...
Page 48: ...Notizen 46...
Page 50: ...8 1 2 11 7 9 10 5 12 4 3 6...
Page 62: ...F r Notizen 14...
Page 108: ...F r Notizen 36...
Page 118: ...Notizen 46...
Page 144: ...5 Buttonhole programming 5 1 Composition of a buttonhole 26...
Page 164: ...Notes 46...
Page 166: ...8 1 2 11 7 9 10 5 12 4 3 6...
Page 178: ...Notes 14...
Page 224: ...Notes 36...