8.
Oil lubrication
Caution: Danger of injury !
Oil can cause skin eruption.
Avoid protracted contact with the skin.
In the event of contact, thoroughly wash the affected area.
ATTENTION !
The handling and disposal of mineral oils is subject to legal
regulations.
Deliver used oil to an authorized collecting station.
Protect your environment.
Take care not to spill oil.
Fill up the oil reservoirs exclusively with lubricating oil
DA-10
or an equivalent oil with the following specification:
–
Viscosity at 40°C:
10 mm²/s
–
Ignition point:
150°C
The oil can be bought at the sales points of
DÜRKOPP ADLER AG
under the following parts numbers:
250-ml-Container:
9047 000011
1-Litre-Container:
9047 000012
2-Litre-Container:
9047 000013
5-Litre-Container:
9047 000014
8.1
Filling the oil reservoir
–
Fill the oil reservoirs 1 and 2 through the hole in the inspection
glasses.
–
The oil level has to be between min. and max.
20