3590EKR, 3590EXP, 3590EXT, 3590 EBOX, CPWE, CPWET series indicator E-AF03_05.01_14.07_EN_T.doc
66
DINI ARGEO REPEATER
[available for ComPc, ComPrn, ComAux]
Transmission protocol for connection to a Dini Argeo weight repeater. It transmits the weight value shown to the Dini Argeo
weight display.
NOTE:
In this case, the setting of the
SEtuP >> SEriAL >> CoM PC >> PC.ModE
parameter has no relevance.
LCD REPEATER (for 3590E version)
[available in ComPc]
With this transmission protocol, it is possible to repeat the messages shown on the LCD display.
The data is transmitted in the following format:
XXXXXXXXXXXXXXXXYYYYYYYYYY CR + LF
in which:
XXXXXXXXXXXXXXXX
=
Data shown on the first line of the LCD display
YYYYYYYYYYYYYYYY
=
Data shown on the second line of the LCD display
CR
=
Carriage Return
LF
=
Line Feed
MONODIRECTIONAL
[available for ComPc]
Through this communication protocol the serial command management is excluded, in order to avoid possible responses to
data received from the port in case of use of the 485 serial line; it can be useful when one uses the port for transmitting a
printout, and various devices are connected on the same 485 line. With this protocol the data and serial command reception
is disabled.
ALIBI MEMORY
[available in ComPc, ComPrn]
If the indicator is fitted with the alibi memory, one should set this parameter in order to store the weighs using the print key
and transmitting the string through the PC serial port; see the protocol specifications in the “ALIBI MEMORY” section in the
user manual.
Furthermore, by enabling the protocol on the ComPC, a string containing the weighing data memorized, will be transmitted.
NOTE:
in the ComPrn the string will not be transmitted.
SMA
[available on ComPC]
Serial communication protocol of the Scale Manufacturers Associations (SMA). See relative manual.
B TYPE
[available in ComPc]
The transmission of the data takes place upon request of the “LAST” command (see section 5.5), in the following format:
$
ASCII decimal character 36 (hexadecimal character 24H).
GGMMAA
Date
HHMM
Time
XXXXXX
Ticket progressive.
YY
First two characters of the contents of the 0 free text.
AAAAAAAAAAAAAAAA
First 16 characters of the material corresponding to the memory
storage identifed by previous YY characters; if the YY characters
are not numerical, or identify an empty memory storage, the contents
of the 0 free text are shown, from the third to the eighteenth character.
BBBBBBBBBBBBBBBB
First 16 characters of the 1 free text contents.
LLLLLLL
Weight greater than the last in/out cycle or gross weight in case of single weigh.
TTTTTTT
Weight less than the last in/out cycle or tare weight in case of single weigh.
NNNNNNN
Weight difference.
CC
Checksum (two hexadecimal ASCII characters, Xor of the bytes up to the weigh difference).
CR
ASCII decimal character 13 (hexadecimal character 0DH).