![Dini Argeo 3590 EBOX Series Technical Manual Download Page 121](http://html.mh-extra.com/html/dini-argeo/3590-ebox-series/3590-ebox-series_technical-manual_2505688121.webp)
3590EKR, 3590EXP, 3590EXT, 3590 EBOX, CPWE, CPWET series indicator E-AF03_05.01_14.07_EN_T.doc
121
XX
is the threshold beginning if
n
= 0 or the characters to be printed if
n
= 1.
616
PRINTS WEIGHT ID VALUE
Values valid in the
nXX
format
In which
n
can be:
0
Value with decimal point and spaces
1
Value with decimal point and zeros in the place of spaces
2
Value without decimal point and zeros in the place of spaces
XX
is the length of the field (maximum enterable value is 20); if the weight value is greater than the number of
entered digits, the complete value is printed anyways.
617
SET PRINTING NUMBER OF CHARACTERS AND DECIMAL NUMBER FOR “PERCENT VALUE OF WEIGHT
INCREMENT/DIMINUTION COMPARED WITH THE INITIAL WEIGHT” MACRO
Values valid in the
nXX
format
In which
n
can be:
0
to set printing characters number;
1
to set number of decimals.
XX
is the number to set.
################
EXAMPLE
If one wants to print the contents of 476 macro (Percent value of weight increment/diminution compared with the
initial weight) in a 6 characters field, with 2 decimal numbers.
…
617 >>> enter parameter 006
617 >>> enter parameter 102
476 (Percent value of weight increment/diminution)
….
################
618
CONDITIONING THE 2
nd
MATERIAL DESCRIPTION PRINTING
Valid values
000
or
001
000
The previous macro can be printed a second time.
001
The previous macro will not be printed a second time.
This macro is valid for the CONDITIONED macros which print the description of the material.
619 SET FORMAT NUMBER OF COPIES
Values valid in the
XXX
format
This macro allows to print the format and a number of its copies equal to
XXX
parameter. The initial format macro is
the macro following this.
################
EXAMPLE
If one wants to print Net Weight, Gross and Tare and then 11 copies.
619 >>> enter parameter 011
301 (Net weight)
302 (Gross weight)
303 (Tare weight)
….
################
620
SET RELAY FUNCTIONING
Values valid in the
nXX
format
In which
n
is the relay status:
0
OFF
1 or 2 ON
XX
is the number of the relay to be enabled, from 00 to 10.