![Dini Argeo 3590 EBOX Series Technical Manual Download Page 81](http://html.mh-extra.com/html/dini-argeo/3590-ebox-series/3590-ebox-series_technical-manual_2505688081.webp)
3590EKR, 3590EXP, 3590EXT, 3590 EBOX, CPWE, CPWET series indicator E-AF03_05.01_14.07_EN_T.doc
81
5.8.1 SERIAL COMMANDS FOR MANAGING THE ALIBI MEMORY:
!! IMPORTANT !!
If the serial commands are transmitted in the format:
<ESC> command <STX>
in which:
<ESC>
is the ASCII decimal 27 character
<STX>
is the ASCII decimal 02 character
Also the relative answer will be:
<ESC> string <STX>
REQUEST WEIGHT VALUE WITH WEIGH ID
The command which allows saving the weight in the alibi memory and the transmission is:
<II>PID<CRLF>
< II >
= machine code, only if functioning in 485
PID
= saving command of the weight data in the alibi memory
CR
= ASCII 13 decimal code
LF
= ASCII 10 decimal code
If the gross weight is equal or greater than zero and stable, the instrument will save the weight on the belt in the alibi
memory.
And the PID string (weight/id) will be transmitted on the PC port; this is described in the following section.
STRING FORMAT (WEIGHT/ID)
The PID string contains all the information regarding the executed weigh.
DESCRIPTION OF THE PID STRING:
<ESC>[II]
PID
SS,B,LLLLLLLLLLUU,YYTTTTTTTTTTUU,(ID | NO) <CR or CRLF>
in which:
[II]
485 address (only in the case of 485 transmission mode)
SS
US instable weight
ST stable weight
OL weight out of range (greater)
UL weight out of range (lower)
,
comma character, ASCII 044
B
number of selected channel
,
comma character, ASCII 044
LLLLLLLLLL
gross weight on 10 digits
UU
unit of measure
,
comma character, ASCII 044
YY
2 spaces in the case of null tare or semiautomatic tare, PT in the case of preset tare
TTTTTTTTTT tare weight on 10 digits
,
comma character, ASCII 044
ID
XXXXX-YYYYYY or “NO”: weigh not stored in the alibi memory; the gross weight is
negative or unstable.
<CR o CRLF> Terminator, ASCII 13 and ASCII 10 characters
WEIGH READING
Command:
[II]ALRDXXXXX-YYYYYY <CR o CRLF>
in which
[II]
485 address (only in the case of 485 transmission mode)
XXXXX
rewriting number, from 0 up to 255.
-
ASCII 045 character
YYYYYY
ID code
<CR o CRLF> terminator, ASCII 13 and ASCII 10 characters