![Dini Argeo 3590 EBOX Series Technical Manual Download Page 75](http://html.mh-extra.com/html/dini-argeo/3590-ebox-series/3590-ebox-series_technical-manual_2505688075.webp)
3590EKR, 3590EXP, 3590EXT, 3590 EBOX, CPWE, CPWET series indicator E-AF03_05.01_14.07_EN_T.doc
75
A bit is ascribed to each input:
Unhandled bits
Expansion board inputs
(optional)
Motherboard
inputs
in.8
in.7
in.6
In.5
in.4
in.3
in. 2
in. 1
Bit
15
Bit
14
Bit
13
Bit
12
Bit
11
Bit
10
Bit
9
Bit
8
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Therefore if the INPU00026 string is received, the hexadecimal value, converted into binary, indicates that the status of the
inputs is the following:
Unhandled bits
Expansion board inputs
(optional)
Motherboard
inputs
in.8
in.7
in.6
in.5
in.4
in.3
in.2
in.1
Bit
15
0
Bit
14
0
Bit
13
0
Bit
12
0
Bit
11
0
Bit
10
0
Bit
9
0
Bit
8
0
Bit
7
0
Bit
6
0
Bit
5
1
Bit
4
0
Bit
3
0
Bit
2
1
Bit
1
1
Bit
0
0
The active inputs are therefore
in.6
,
in.3
of the optional board and
in.2
of the motherboard.
NOTES:
- With the bits 8 to 15, no input is assigned, and are fixed at zero
- The reading command of the inputs works also in the set-up environment
[INUN] Request of a numeric value entry on the 3590E LED display (only for 3590e version):
Syntax
Format
<CC>INUN<X>,<M>,<H>,< I >,<L>,<D>,<P><CR LF>
Parameters
X = numeric or alphanumeric character (0 – 9 ; A – Z ; a – z) displayable
in the digit on the extreme left of the 3590E LED display / CPWE
weight section (not modifiable);
M = minimum enterable value in decimals (0 ≤ M ≤ H)
H = maximum enterable value in decimals
(0 ≤ H ≤ 999'999'999'999'999'999,18 digits).
I = value displayed initially in decimals, substituted then by the entered
one (M ≤ I ≤ H); if the entered value is less than the enterable
minimum value (M), the minimum value will initially be displayed (M).
L = maximum number of enterable characters in decimals
( 0 ≤ L ≤ 18)
D = number of decimal digits (in decimals)
P = initial position in decimals of the blinking digit (in other words the
position of the first value to be modified).
- if P = 0, the blinking digit is the least significant one
- if P = 1, the blinking digit is the most significant one
Answer
<CC>OK<CR LF>
Example
01INUNt,0,10000,0,5,3,0<CR LF>
Result
The t 00.000 message appears on the 3590E LED display weight section
with the least significant digit blinking, while waiting for the entry of a
numeric value
If the entered value is greater or less respectively to the maximum or minimum set value, the instrument will emit an error
sound signal.