<< A.inout
>>
AUTOMATIC IN OUT WEIGHT
In this step you can enable (
ENABLED
) or disable (
DISABLED
) automatic input output function or print (
SIMPLE
PRINTOUT
) when vehicle is selected. When this step is enabled, in the vehicle selection moment is request
automatically the input weight, after, when you reselect the same vehicle will be request automatically the output
weight. This step is appropriate for the SELF SERVICE with badge reader.
In this way when you swipe the badge the indicator identify the veichle and it executes automatically the setted
printout (input/output or simple printout).
(REF.NOT.U.)
(!) DISABLED
<< SELF.C
>>
SELF-SERVICE CONFIGURATION
This step is displayed only if
F.ModE >> totAL >> A.inout
is enabled (
ENABLED
) or set to simple printout (
SIMPLE
PRINTOUT
) or if the protocol
COIN
is enabled for the COIN on COMPC or COMAUX.
<< r.S.WGht >>
WEIGHT THRESHOLD LEVEL INDICATOR
:
threshold beyond which authentication is required by
badge card or credit to see or ptiny the weight . Beyond this treshold are displayed dashes "-----" instead of weight.
Once you have selected the vehicle (eg. with the badge) or added the credit requested (in case of COIN) displays the
weight on the scale for a maximum time equal to the seconds set in MAX TIME END OPERATION.
(!) 000000
<< dF.WGht >>
WEIGHT DIFFERENCE TO WEIGHT THE END: after the acquisistion and display of the weight, if
this increases or decreases by a value greater than this second treshold, the instrument redisplays “------“.
EXAMPLE OF USE:
You have two trucks in line and at the end of the weighing of the first, the second does not make the balance return
to zero. If in this case the treshold is not set in the balance, this one goes in error .
(!) 000000
<< r.Auto0 >>
AUTOMATIC AUTOZERO TRESHOLD: treshold (in absolute value) within whch if the weight is
different from zero, remains stable for the time set in the step TIME STABILITY and persist for the time set in the step
TIME AUTOZERO, the instrument perform automatic zero.
EXAMPLE OF USE: you set 40 kg of treshold, TIME STABILITY= 5 s, TIME AUTOZERO = 10 s. If the weight on the
scale is 10 kg and stable, it is reset automatically after 10 second.
(!) 000000
<< t.Auto0 >>
TIME AUTOZERO: time in seconds that must elapse before performing the autozero procedure (step
conditional to stability).
(!) 000000
<< t.Stabi >>
TIME STABILITY: time in seconds that I have exactly the same weight to be able to declare stable.
(!) 01 sec
<< t.End >>
MAX TIME END TRANSACTION: maximum time after which the operation ends. If you perform an
operation and the trucks remains on the weighing, after this time, however, declares ended weighing and requires re-
authentication.
Consigliato:
10-20 seconds.
<< t.MonEY >>
MAX TIME WAITING CREDIT: (only with coin and protocol COIN enabled) Maximum time to wait the
coin before declare however ended the operation. The time is reset at each introduction of the coin.
(!) 00 sec
LOCK KEYBOARD
: if enabled lock all key.
(!) DISABLED
<< rEACt. >>
REACTIVATIONS
It is possible to set whether to reactivate the printout and the input/output weigh through: