![Dini Argeo 3590 EBOX Series Technical Manual Download Page 67](http://html.mh-extra.com/html/dini-argeo/3590-ebox-series/3590-ebox-series_technical-manual_2505688067.webp)
3590EKR, 3590EXP, 3590EXT, 3590 EBOX, CPWE, CPWET series indicator E-AF03_05.01_14.07_EN_T.doc
67
riP. b
[available in ComPc]
The transmission of the weight data on the serial port takes place in the following format:
$FPPPPP <CR>
in which:
$ = ASCII decimal character 36 (ASCII hexadecimal 24H).
F =
0 with stable weight;
1 with instable weight;
3 with negative weight, in underload or in overload.
PPPPP = Net Weight on 5 digits, without sign or decimal point.
<CR> = ASCII decimal character 13 (hexadecimal character 0DH).
NOTE:
-
the string is valid for all the available transmission modes described in section 5.5.
-
the recommended communication protocol for
b
type data transmission include
Baud rate
=
4800
,
Parity
=
Even
,
Word
=
7
,
Stop bit
=
2
.
“PRINT”
[available for ComPrn]
The weight data transmission on the serial port depends on the print functions of the indicator.
For further details see section 7 “PROGRAMMING THE PRINTOUTS” and section 14 “PRINTOUTS”
USER MAN.REF.
riPEdC
[available for ComAuX]
In this case one can configure up to three weight repeaters so that each one displays different information.
Selecting the
“
riPEdC
“
protocol it’s possible to configure:
-
the
“
dSP1
“
repeater having 01 address so that it receives the weight from scale 1;
-
the
“
dSP2
“
repeater having 02 address so that it receives the weight from scale 2;
-
the
“
dSPSum
“
repeater having 03 address so that it receives the sum weight.
For each of them it’s possible to choose if:
-
NO
disable entry of data;
-
ONLY IF SELECTED
send data only if the corresponding scale is selected on the display of the indicator;
-
ALWAYS
send data independently from the selected scale on the display of the indicator.
5.5 TRANSMISSION MODES
Data transmission from PC Serial Port can be done in 5 different ways:
TRANSMISSION ON REQUEST
[available in ComPC]
It requires an external command from the PC to send the data requested. Transmission can take place at any time
requested.
CONTINUOUS TRANSMISSION
[available in ComPC, ComPrn, ComAux]
- ComPC:
Continuous transmission of the standard string (
ProtoC
=
StAnd
step), or of the extended AF0X string
(
ProtoC
=
AF0X
step) or continuous transmission of the personalised string.
This mode is used for interfacing with computers, remote displays and other devices that require a constant
update of data regardless of weight stability (10 transmissions per second with Baud rate at 9600 and
stable weight).
- ComPrn:
The indicator transmits continuously the data configured in the 01 print format.
Alternatively, by setting only the “300” block in the 01 print format, it is possible to transmit the STANDARD
STRING (or the AF0X STRING, if configured for the PC port).
For configuration details of the print formats, see section 7.
- ComAux:
The weight transmission on the serial port takes place with the STANDARD protocol.