SETS UNIT OF MEASURE IN THE ACCUMULATOR VALUE
Values valid in the
XXX
format
in which
XXX
can be:
000
g
001
kg
002
t
003
lb
NOTE: if no unit of measure has been set, the one of the scale is used.
629
PRINTS THE LOADED VALUE IN THE ACCUMULATOR
Values valid in the
nXX
format
In which
n
can be:
0
Value with decimal point and spaces
1
Value with decimal point and zeros in the place of spaces
2
Value without decimal point and zeros in the place of spaces
XX
is the length of the field (maximum enterable value is 20); if the weight value is greater than the number of
entered digits, the complete value is printed anyways.
################
EXAMPLE
The scale is with three decimals and the unit of measure is the kg; one wants to print the net weight with two
decimals converted in pounds, expressed in 7 digits without decimal points, with non significant zeros filling in the
eventual spaces present.
One should set the following macros:
…
626 >>> enter parameter 000
627 >>> enter parameter 002
628 >>> enter parameter 003
629 >>> enter parameter 207
….
If the net weight of the scale corresponds to 2,480 kg, the printed value will be
0000547
################
630 SETS THE VALUE OF THE SETPOINT IN THE ACCUMULATOR
Values valid in the
XXX
format
Parameter
ON Threshold (setpoint)
=========
==================
000 ~ 003
rL.1 ~ 4
004 ~ 015
rL.5 ~ 16
Parameter
OFF Threshold (setpoint)
=========
==================
016 ~ 019
rL.1 ~ 4
020 ~ 031
rL.5 ~ 16
633 FORCES PRINTOUT AND TIME WAIT Values valid in the
XXX
format
Besides the force printout function, it waits also a period of time.
XXX
Wait time (max 200dsec); for example “001” is equal to 0,1 seconds; “010” equals to 1 second.
646 EAN/UCC CHECKDIGIT ON X PREVIOUS DIGITS
Values valid in the
XX
format
647 FOLLOWING MACROS TERMINATORS SKIPS
Valori validi nella forma
XXX
in which
XXX
can be:
001
in order to skip the terminators of all the following macros
000