Serial port
Configure Login mode
Digi Connect EZ Mini User Guide
84
n
RS-232
l
Enable
RTS Toggle
if you want to enable RTS toggling during transmission on this
serial port. If enabled, this setting overrides RTS\CTS flow control.
l
For
RTS Pre-delay
, enter the amount of time RTS is asserted before starting data
transmission. The time is measured in milliseconds. The default is
0ms
.
l
For
RTS Post-delay
, enter the amount of time RTS is deasserted before completing
data transmission. The time is measured in milliseconds. The default is
0ms
.
n
RS-422
l
Enable
Termination
if you want to enable electrical termination on this serial port.
n
RS-485
l
Enable
Termination
if you want to enable electrical termination on this serial port.
l
Enable
Full Duplex
if you want to enable full duplex communication on this serial
port.
The default is
RS-232
.
8. Expand
Serial Settings
.
The entries in the following fields must match the information for the power controller. Refer
to your power controller manual for the correct entries.
a.
Baud rate
: For
Baud rate
, select the baud rate used by the device to which you want to
connect. The default is
9600
.
b.
Data bits
: For
Data bits
, select the number of data bits used by the device to which you
want to connect. The default is
8
.
c.
Parity
: For
Parity
, select the type of parity used by the device to which you want to
connect. The default is
None
.
d.
Stop bits
: For
Stop bits
, select the number of stop bits used by the device to which you
want to connect. The default is
1
.
e.
Flow control
: For
Flow control
, select the type of flow control used by the device to
which you want to connect. The default is
None
.
9. Click
Apply
to save the configuration and apply the change.
The
Apply
button is located at the top of the WebUI page. You may need to scroll to the top of
the page to locate it.