![Digi Connect EZ Mini User Manual Download Page 109](http://html.mh-extra.comconnect-ez-mini_user-manual_2496436109.png)
Serial port
Configure Modbus mode
Digi Connect EZ Mini User Guide
109
The entries in the following fields must match the information for the power controller. Refer
to your power controller manual for the correct entries.
a.
Baud rate
: For
Baud rate
, select the baud rate used by the device to which you want to
connect. The default is
9600
.
b.
Data bits
: For
Data bits
, select the number of data bits used by the device to which you
want to connect. The default is
8
.
c.
Parity
: For
Parity
, select the type of parity used by the device to which you want to
connect. The default is
None
.
d.
Stop bits
: For
Stop bits
, select the number of stop bits used by the device to which you
want to connect. The default is
1
.
e.
Flow control
: For
Flow control
, select the type of flow control used by the device to
which you want to connect. The default is
None
.
1. Set the baud rate used by the device to which you want to connect:
(config)>path-parambaudrate
rate
(config)>
2. Set the number of data bits used by the device to which you want to connect:
(config)>path-paramdatabits
bits
(config)>
3. Set the type of parity used by the device to which you want to connect:
(config)>path-paramparity
parity
(config)>
Allowed values are:
n
even
n
odd
n
none
The default is
none
.
4. Set the stop bits used by the device to which you want to connect:
(config)>path-paramstopbits
bits
(config)>
9. Click
Apply
to save the configuration and apply the change.
The
Apply
button is located at the top of the WebUI page. You may need to scroll to the top of
the page to locate it.