![Digi Connect EZ Mini User Manual Download Page 587](http://html.mh-extra.comconnect-ez-mini_user-manual_2496436587.png)
Diagnostics
Configure options for the event and system logs
Digi Connect EZ Mini User Guide
587
ii. To disable informational messages for the DHCP server:
(config)> system log event dhcpserver info false
(config)>
iii. To change the status interval:
(config)> system log event dhcpserver status_interval
value
(config)>
where
value
is any number of weeks, days, hours, minutes, or seconds, and takes the
format
number
{
w|d|h|m|s
}.
For example, to set
the status interval
to ten minutes, enter either
10m
or
600s
:
(config)> system log event dhcpserver status_interval 600s
(config)>
6. (Optional) See
for information about configuring remote syslog
servers to which log messages will be sent.
7. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
8. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.