Serial port
Configure RealPort mode
Digi Connect EZ Mini User Guide
100
(config)> serial port1 rts_post_delay
value
(config)>
n
rs-422
l
Enable
Termination
if you want to enable electrical termination on this serial port.
n
rs-485
l
Enable
termination
if you want to enable electrical termination on this serial port:
(config)> serial port1 termination true
(config)>
l
Enable
full_duplex
if you want to enable full duplex communication on this serial
port:
(config)> serial port1 full_duplex true
(config)>
The default is
rs-232
.
5. Enable
Altpin
to use the Altpin feature.
Altpin
is disabled by default.
(config)> serial port1 altpin true
(config)>
This feature should be enabled when you are using a modem and an 8-pin cable and you need
CD (Carrier Detect). When enabled, the DTR on pin 1 drives DCD.
If altpin is disabled, the hardware signal on RJ45 pin 1 becomes DSR instead of DCD. This
alternative can be used if DCD is not required, and DSR is needed instead.
6. Set a label that will be used when referring to this port.
(config)> serial port1 label
label
(config)>
7. (Optional) Set a label that will be used when referring to this port.
(config)> serial port1 label
label
(config)>
8. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
9. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.