![Digi Connect EZ Mini User Manual Download Page 636](http://html.mh-extra.comconnect-ez-mini_user-manual_2496436636.png)
Command line interface
Command line reference
Digi Connect EZ Mini User Guide
636
system power ignition off_delay
analyzer clear
Clears the traffic captured by the analyzer.
Syntax
analyzer clear <name>
Parameters
name: Name of the capture filter to use.
analyzer save
Saves the current captured traffic to a file.
Syntax
analyzer save <name> <filename>
Parameters
name: Name of the capture filter to use.
filename: The filename to save captured traffic to. The file will be saved to the device's
/etc/config/analyzer directory.
analyzer start