Table 12 - 2 Operating Troubleshooting - Data
ITEM CONDITION/INDICATION
POSSIBLE MALFUNCTION
CORRECTIVE ACTION
1 Control Panel Inoperative
Control Panel not connected
properly or damaged
Check cable connection on rear of
AVCS.
Inspect cables and connectors for
damage, if damaged replace cables.
Control Panel unserviceable
Disconnect Control panel and access
AVCS using external computer
connection. If AVCS operates
normally, continue mission, notify
service maintenance
Control Processor MSG
indicator light lit
Turn off power to system and restart.
Test system operation
NOTE: the MSG light does
not always mean there is a
problem. The MSG light
indicates that something has
been written to the
processor’s log file.
Notify Service Maintenance
2
Control Panel functions
Non-operational
System needs to be reset
Turn off power to system and restart.
Test system operation
Notify Service Maintenance
END OF TASK
Summary of Contents for TM 95263 00
Page 2: ......
Page 8: ......
Page 10: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 30: ......
Page 31: ...DHS Systems LLC TM 95236 00 CHAPTER 2 OPERATOR INSTRUCTIONS FOR AVCS MINI...
Page 32: ......
Page 48: ......
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...DHS Systems LLC TM 95236 00 CHAPTER 3 OPERATOR TROUBLESHOOTING PROCEDURES FOR AVCS MINI...
Page 92: ......
Page 100: ......
Page 106: ......
Page 107: ...DHS Systems LLC TM 95236 00 CHAPTER 4 OPERATOR MAINTENANCE INSTRUCTIONS FOR AVCS MINI...
Page 108: ......
Page 112: ......
Page 116: ......
Page 122: ......
Page 123: ...DHS Systems LLC TM 95236 00 CHAPTER 5 SUPPORTING INFORMATION FOR AVCS MINI...
Page 124: ......
Page 130: ......
Page 132: ......