Chapter 4 Parameters
|
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
4-41
3 chances to enter the correct
password.
1st time displays "1" if
password is incorrect.
2nd time displays "2", if
password is incorrect.
3rd time displays " code"
(blinking)
If the password was entered
incorrectly after three tries,
the keypad will be locked.
Turn the power OFF/ON to
re-enter the password.
Incorrect Password
END
Displays 0 when
entering correct
password into
Pr.00.08.
00.09
00.08
00.08
Displays 0 when
entering correct
password into
Pr.00.08.
Correct Password
END
00.09
00.10
Control Method
Factory Setting: 0
Settings
0
V/f
Control
1
Vector
Control
This parameter determines the control method of the AC motor drive.
00.11
Reserved
00.12
50Hz Base Voltage Selection
Factory Setting: 0
Settings
0
230V/400V
1
220V/380V
This parameter determines the base voltage for 50Hz.
Summary of Contents for AC Motor Drive VFD-E
Page 1: ......
Page 2: ......
Page 3: ......
Page 13: ...This page intentionally left blank...
Page 233: ......
Page 274: ...Appendix B Accessories Revision June 2008 04EE SW PW V1 11 CTL V2 11 B 37...