Appendix D How to Use PLC Function
|
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
D-29
D.5.2 Output Commands
Commands
Function
Operands
OUT
Drive coil
Y, M
SET
Action latched (ON)
Y, M
RST
Clear the contacts or the registers
Y, M, T, C, D
D.5.3 Timer and Counters
Commands
Function
Operands
TMR
16-bit timer
T-K or T-D
CNT
16-bit counter
C-K or C-D
D.5.4 Main Control Commands
Commands
Function
Operands
MC
Connect the common series connection
contacts
N0~N7
MCR
Disconnect the common series connection
contacts
N0~N7
D.5.5 Rising-edge/falling-edge Detection Commands of Contact
Commands
Function
Operands
LDP
Rising-edge detection operation starts
X, Y, M, T, C
LDF
Falling-edge detection operation starts
X, Y, M, T, C
ANDP
Rising-edge detection series connection
X, Y, M, T, C
ANDF
Falling-edge detection series connection
X, Y, M, T, C
ORP
Rising-edge detection parallel connection
X, Y, M, T, C
ORF
Falling-edge detection parallel connection
X, Y, M, T, C