Appendix D How to Use PLC Function
|
D-28
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
NOTE: when it is in PLC1 mode, the communication address will correspond to the parameter NOT
the device. For example, address 0400H will correspond to Pr.04.00 NOT X0.
D.4.11 Function Code (only for PLC2 mode)
Function Code
Description
Supported Devices
01
Read coil status
Y, M, T, C
02
Read input status
X, Y, M, T, C
03
Read one data
T, C, D
05
Force changing one coil status
Y, M, T, C
06
Write in one data
T, C, D
0F
Force changing multiple coil status
Y, M, T, C
10
Write in multiple data
T, C, D
D.5 Commands
D.5.1 Basic Commands
Commands
Function
Operands
LD
Load contact A
X, Y, M, T, C
LDI
Load contact B
X, Y, M, T, C
AND
Series connection with A contact
X, Y, M, T, C
ANI
Series connection with B contact
X, Y, M, T, C
OR
Parallel connection with A contact
X, Y, M, T, C
ORI
Parallel connection with B contact
X, Y, M, T, C
ANB
Series connects the circuit block
--
ORB
Parallel connects the circuit block
--
MPS
Save the operation result
--
MRD
Read the operation result (the pointer not moving)
--
MPP
Read the result
--
INV
Inverter the result
--