![Delta Electronics AC Motor Drive VFD-E User Manual Download Page 316](http://html1.mh-extra.com/html/delta-electronics/ac-motor-drive-vfd-e/ac-motor-drive-vfd-e_user-manual_2476007316.webp)
Appendix D How to Use PLC Function
|
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
D-33
Program Example:
Ladder diagram:
Command code:
Operation:
LD
X0
Load contact A of X0
OR
X1
Connect to contact A of
X1 in parallel
X0
X1
Y1
OUT
Y1
Drive Y1 coil
Mnemonic Function
ORI
Parallel connection- B contact
X0~X17 Y0~Y17
M0~M159 T0~15 C0~C7 D0~D29
Operand
9
9
9
9
9
--
Explanations:
The ORI command is used in the parallel connection of B contact. The function of the command is to
readout the status of present specific series connection contacts, and then to perform the “OR”
calculation with the logic calculation result before the contacts, thereafter, saving the result into the
accumulative register.
Program Example:
Ladder diagram:
Command code:
Operation:
LD
X1
Load contact A of X0
ORI
X1
Connect to contact B of
X1 in parallel
X0
X1
Y1
OUT
Y1
Drive Y1 coil
Mnemonic Function
ANB
Series connection (Multiple Circuits)
Operand
None
Explanations:
To perform the “ANB” calculation between the previous reserved logic results and contents of the
accumulative register.
Summary of Contents for AC Motor Drive VFD-E