Appendix B Accessories
|
B-8
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
B.2 No-fuse Circuit Breaker Chart
For 1-phase/3-phase drives, the current rating of the breaker shall be greater than 2 X (rated input
current).
1-phase 3-phase
Model
Recommended
no-fuse
breaker (A)
Model
Recommended
no-fuse
breaker (A)
VFD002E11A/11T/11C/
11P
15 VFD002E23A/23C/23T/
23P
5
VFD002E21A/21T/21C/
21P
10 VFD004E23A/23C/23T/
23P
5
VFD004E11A/11C/11T/
11P
20 VFD004E43A/43C/43T/
43P
5
VFD004E21A/21C/21T/
21P
15 VFD007E23A/23C/23T/
23P
10
VFD007E11A/11C 30
VFD007E43A/43C/43T/
43P
5
VFD007E21A/21C/21T/
21P
20 VFD015E23A/23C/23T/
23P
20
VFD015E21A/21C 30
VFD015E43A/43C/43T
10
VFD022E21A/21C 50 VFD022E23A/23C 30
VFD022E43A/43C
15
VFD037E23A/23C
40
VFD037E43A/43C
20
VFD055E23A/23C
50
VFD055E43A/43C
30
VFD075E23A/23C
60
VFD075E43A/43C
40
VFD110E43A/43C
50