Appendix D How to Use PLC Function
|
D-32
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
Mnemonic Function
ANI
Series connection- B contact
X0~X17 Y0~Y17
M0~M159 T0~15 C0~C7 D0~D29
Operand
9
9
9
9
9
--
Explanations:
The ANI command is used in the series connection of B contact. The function of the command is to
readout the status of present specific series connection contacts first, and then to perform the “AND”
calculation with the logic calculation result before the contacts, thereafter, saving the result into the
accumulative register.
Program Example:
Ladder diagram:
Command code:
Operation:
LD
X1
Load contact A of X1
ANI
X0
Connect to contact B of
X0 in series
X0
X1
Y1
OUT
Y1
Drive Y1 coil
Mnemonic Function
OR
Parallel connection- A contact
X0~X17 Y0~Y17
M0~M159 T0~15 C0~C7 D0~D29
Operand
9
9
9
9
9
--
Explanations:
The OR command is used in the parallel connection of A contact. The function of the command is to
readout the status of present specific series connection contacts, and then to perform the “OR”
calculation with the logic calculation result before the contacts, thereafter, saving the result into the
accumulative register.
Summary of Contents for AC Motor Drive VFD-E
Page 1: ......
Page 2: ......
Page 3: ......
Page 13: ...This page intentionally left blank...
Page 233: ......
Page 274: ...Appendix B Accessories Revision June 2008 04EE SW PW V1 11 CTL V2 11 B 37...