Group 7 Motor Parameters
Parameter Explanation
Settings
Factory
Setting
Customer
07.00
Motor Rated Current
(Motor 0)
30 %FLA to 120% FLA
FLA
07.01
Motor No-Load
Current (Motor 0)
0%FLA to 99% FLA
0.4*FLA
07.02
Torque
Compensation
(Motor 0)
0.0 to 10.0
0.0
07.03 Slip
Compensation
(Used without PG)
(Motor 0)
0.00 to 10.00
0.00
07.04
Motor Parameters
Auto Tuning
0: Disable
1: Auto tuning R1
2: Auto tuning R1 + no-load test
0
07.05
Motor Line-to-line
Resistance R1
(Motor 0)
0~65535 m
Ω
0
07.06
Motor Rated Slip
(Motor 0)
0.00 to 20.00 Hz
3.00
07.07
Slip Compensation
Limit
0 to 250%
200
07.08
Torque
Compensation Time
Constant
0.01 ~10.00 Sec
0.10
07.09
Slip Compensation
Time Constant
0.05 ~10.00 sec
0.20
07.10
Accumulative Motor
Operation Time
(Min.)
0 to 1439 Min.
0
07.11
Accumulative Motor
Operation Time
(Day)
0 to 65535 Day
0
07.12
Motor PTC
Overheat Protection
0: Disable
1: Enable
0
07.13
Input Debouncing
Time of the PTC
Protection
0~9999(*2ms) 100