Replacing a power supply
6
Replacing a power supply
You can replace an power supply while the BigIron RX Series chassis is powered on and running.
The power supplies are located in slots along the bottom of the BigIron RX Series chassis.
CAUTION
If hot removing or inserting a module, please allow a minimum of 2 seconds after a module (or
power supply or fan tray) has been removed before inserting a module in the same slot.
This section provides information about the following topics:
•
Determining which AC or DC power supply has failed, if necessary
•
Replacing a AC or DC power supply
Determining which power supply failed
To determine which power supply has failed, enter the following command at any CLI command
prompt:
BigIron RX# show chassis
This command displays status information for the fans and power supplies, and temperature
readings for various components in the chassis. The power supplies are numbered in the display.
If the display indicates “Installed (Failed)” for any of the slots, the power supply installed in that
particular slot has failed or is not properly installed.
Replacing a power supply
To replace a power supply, you need the following:
•
A new power supply (AC or DC), which you can order from Brocade
•
A small flathead or Phillips screwdriver (BigIron RX-4 only)
DANGER
The power supplies are hot swappable, which means they can be removed and replaced while
the BigIron RX Series chassis is powered on and running. However, Brocade recommends that
you disconnect the power supply from its power source before removing and replacing the
Summary of Contents for BigIron RX-16
Page 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Page 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Page 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Page 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Page 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Page 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...