BigIron RX Installation Guide
149
53-1001811-01
Replacing a power supply
6
FIGURE 76
Removing and replacing a BigIron RX-32 power supply
6. Continue to pull the power supply until it is removed from the chassis.
7. Insert the new power supply into the empty power supply slot, using the guides provided on
either side of the slot.
CAUTION
Carefully follow the mechanical guides on each side of the power supply slot and make sure the
power supply is properly inserted in the guides. Never insert the power supply upside down.
1
Power supply indicators
6
Latch handle locked
2
AC OK
7
Power supply blank cover
3
DC OK
8
Pull down on plunger to remove
4
ALM
9
Power supply
5
Latch handle open
Pw
r