BigIron RX Installation Guide
115
53-1001811-01
Managing the BigIron RX Series chassis
5
Displaying the Syslog configuration and static and
dynamic buffers
For information about configuring Syslog, refer to the
BigIron RX Series Configuration Guide
To display the Syslog parameters currently in effect on a BigIron RX Series switch, enter the
following command from any level of the CLI:
Syntax: show logging
The Syslog display shows the following configuration information, in the rows above the log entries
themselves.
Status
The status of a fan can be one of the following:
•
OK – The fan is functioning properly and is keeping the temperature of
each module within an acceptable temperature range.
•
Failed – The fan is not functioning properly or the fan control module
cannot control the fan.
Speed
The speed of a fan can be one of the following:
•
Low – The fan is functioning at 50 percent of capacity.
•
Medium – The fan is functioning at 75 percent of capacity.
•
Medium-high – The fan is functioning at 90 percent of capacity.
•
High – The fan is functioning at 100 percent of capacity.
Temperature Readings
Active and Standby Mgmt Module
The temperature of the active and standby management modules.
Fan <number>
The temperature of fan0 and fan1.
SNM<number>
The temperature of the switch fabric module.
Temperature Monitoring Poll Period
The interval at which the system reads the temperature sensor on the
management, switch fabric, interface, and fan control modules.
Misc Info
Backplane EEPROM MAC Address
The MAC address of the BigIron RX Series chassis.
TABLE 19
Syslog buffer configuration
This field...
Displays...
Syslog logging
The state (enabled or disabled) of the Syslog buffer.
messages dropped
The number of Syslog messages dropped due to user-configured filters.
By default, the software logs messages for all Syslog levels. You can
disable individual Syslog levels, in which case the software filters out
messages at those levels. Each time the software filters out a Syslog
message, this counter is incremented.
TABLE 18
Chassis status and temperature information (Continued)
This field...
Displays...
BigIron RX> show logging
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 7 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
...
Summary of Contents for BigIron RX-16
Page 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Page 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Page 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Page 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Page 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Page 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...